Viscous torque (windage) of a Lundell-shaped rotor having a major diameter of 20.3 cm (8 in.) rotating within a concentric housing was measured at speeds up to 36,000 rpm. The center cylindrical section of the housing was tested with both a smooth surface and axial slots to simulate alternator winding slots. For concentric cylinders, the range of Reynolds numbers was extended to 70,000. Three radial clearances, 1, 2, and 4 mm (0.04, 0.08, and 0.16in.), corresponding to 1, 2, and 4 percent of the rotor radius, were tested.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Correlation of windage-loss data for a Lundell alternator


    Contributors:

    Publication date :

    1972-02-01


    Type of media :

    Miscellaneous


    Type of material :

    No indication


    Language :

    English




    Correlation of Windage-Loss Data for a Lundell Alternator

    E. E. Kempke / S. H. Gorland | NTIS | 1972


    Correlation of windage-loss data for a Lundell alternator

    Kempke, Erwin E. / Gorland, Sol H. | TIBKAT | 1972



    Mosfets used in ideal diode circuits for Lundell alternator rectifiers