A full-scale, mixed-compression inlet was designed for operation with the TF30-P-3 turbofan engine and tested at Mach numbers of 2.5 and 2.0. The two-cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery was 0.906 with only 0.021 centerbody bleed mass-flow ratio and no cowl bleed. Increased centerbody bleed gave a maximum inlet unstart angle of attack of 6.85 deg. At Mach 2.0, inlet recovery was 0.94 with only 0.014 centerbody bleed mass-flow ratio and no cowl bleed. Inlet performance and angle-of-attack tolerance is presented for operation at Mach numbers of 2.5 and 2.0. (Author)
Design of a Very-Low-Bleed Mach 2.5 Mixed-Compression Inlet with 45 Percent Internal Contraction
1975
71 pages
Report
No indication
English