A detailed investigation to determine the applicability of radiochemical exchange techniques, using 'Kryptonates', as a system for detecting hydrogen vapor concentrations of 1% or less, aboard aerospace flight vehicles, was conducted. The optimum host material was found to be a 50-50 mixture of aluminum oxide and kryptonated platinum dioxide. This mixture can detect hydrogen in concentrations less than 1% with a response time of less than 0.5 seconds. An experimental model demonstrating the feasibility and applicability of the kryptonate detection system was constructed. (Author)


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Detection of Hydrogen Aboard Aerospace Flight Vehicles


    Contributors:
    O. Cucchiara (author) / T. Donaghue (author) / D. Chleck (author)

    Publication date :

    1964


    Size :

    2 pages