This paper will present the final tests of the APS storage ring BPM electronic system. The final configuration includes the filter-comparator installed in the accelerator tunnel and the signal conditioning and digitizing unit (SCDU) in a VXI configuration. The SCDU includes an AM/PM monopulse receiver at 352 MHz. Extensive testing was performed on the system. The key parameters measured were the null cancellation better than 45 db, dynamic range of better than 40 db, single bunch capability with 0.01 mA sensitivity, and a resolution better than 10 micrometers for 512 averaged turns. This last critical performance was tested using a moving wire to simulate the beam. This report will concentrate on the wire test results. Also, the actual production hardware will be presented.