The paper gives a survey of the formulations for an analytical description of the containment performance during LOCA and indicates the essential parameters of influence. The analytically relevant heat transfer conditions and air transport mechnisms within the containment are treated in more detail. The heat transfer relations established are part of the containment code CORAN developed at GKSS. Their influence on the analytical results is demonstrated by the example of the Batelle experiment D1. (Atomindex citation 10:448907)