These criteria define the requirements for the construction of a maritime prototype test facility (MPTF) at Test Areas North (TAN), National Reactor Testing Station in Idaho. The maritime prototype test area will be located approximately 5000 feet southeast of the existing LPT and EBOR facilities and 2-1/4 miles southeast of the Technical Support Facilities (TSF). The facility shall be connected to the TSF area by a paved road. The Maritime Prototype Test Facility is basically a single purpose, isolation type installation consisting of three major inter-related components as follows: the test building enclosing the 630A Nuclear Steam Generator; an auxiliary test equipment building; and a control and equipment building. The major components of the maritime prototype test facility are adjacent to each other and are attached together. A detailed description including functions, relationships and construction features of the major components of the maritime prototype test facility are presented. (ERA citation 10:004706)
Design Criteria Maritime Prototype Test Facility (2ND Issue)
1963
55 pages
Report
No indication
English
Maritime administration prototype ship
Engineering Index Backfile | 1951
Emission facility design criteria
Automotive engineering | 1979
|Emission facility design criteria
Tema Archive | 1979
|Emission Facility Design Criteria
SAE Technical Papers | 1979
|