When the APS storage ring was retuned to provide smaller (beta)(sub y) values in the insertion straight sections, it was necessary to increase the vertical tune by at least two units. Since the design values for the horizontal and vertical tunes are 35.22 and 16.30, respectively, this put the tunes dangerously close to the sextupole 2v(sub y)-v(sub x) coupling resonance. The large injection horizontal oscillations could couple to the vertical plane and exceed the 5-mm vertical apertures that exist in some of the insertion straight sections. To avoid this resonance, the vertical tune was raised beyond the resonance to 19.30. The result was a reduction in the ability of the chromaticity sextuples to correct the chromaticity. Recent investigation has shown that the chromaticity correction capability of the sextuples can be greatly increased by a modest increase in the horizontal tune. Increasing the horizontal tune by one unit and reducing the vertical tune by three units produces a lattice with better chromaticity control while maintaining an acceptable dynamic aperture.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Retuning the APS storage ring for better chromaticity correction


    Contributors:
    Y. C. Chae (author) / E. A. Crosbie (author)

    Publication date :

    1999


    Size :

    13 pages


    Type of media :

    Report


    Type of material :

    No indication


    Language :

    English





    Illumination Chromaticity Estimation Using Inverse-Intensity Chromaticity Space

    Tan, R. / Nishino, K. / Ikeuchi, K. et al. | British Library Conference Proceedings | 2003



    Retuning the actuator proportional–integral–derivative controller of spinning missiles

    Zhou, Wei / Yang, Shuxing / Zhao, Liangyu | SAGE Publications | 2017