Electromagnetic Interference (EMI) noise is one of the major issues during the design of the grid-tied power converters. Presence of high dv/dt in Common Mode (CM) voltage, excites the parasitic capacitances and causes injection of narrow peaky current to ground. This results in high EMI noise level. A topology consisting of a single phase PWM-rectifier with LCL filter, utilising bipolar PWM method is proposed which reduces the EMI noise level by more than 30dB. This filter topology is shown to be insensitive to the switching delays between the legs of the inverter. The proposed topology eliminates high dv/dt from the dc-bus CM voltage by making it sinusoidal. Hence, the high frequency CM current injection to ground is minimized.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Filter configuration and PWM method for single phase inverters with reduced conducted EMI noise


    Contributors:


    Publication date :

    2014-08-01


    Size :

    987664 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Eliminating Common Mode Conducted Emissions in Three-Phase Four-Leg Inverters

    Julian, Alexander L. / Oriti, Giovanna / Krener, Arthur J. | IEEE | 2021


    Prediction of conducted EMI in three phase inverters by simulation method

    Zhuolin, Duan / Dong, Zhang / Tao, Fan et al. | IEEE | 2017


    Reduced-parts three-phase inverters: A comparative study

    Haizhong Ye, / Bilgin, Berker / Emadi, Ali | IEEE | 2012


    Mitigation of Second Harmonic Pulsations for Single-Phase Inverters

    Zhou, Liwei / Jahnes, Matthew / Silverman, Noah et al. | IEEE | 2023