An Analysis of a dual three-phase induction machine under open-circuit operating conditions is presented in this paper. A fast analytical method of determining the harmonic content of the MMF distribution in the air gap is derived by means of a symmetrical component analysis of the stator winding MMF. The method summarizes the harmonics into groups of infinite Fourier series, which simplifies the analysis especially in post-fault operation. Furthermore, the post-fault load capability for constant loads was determined with phase currents exceeding the rated value. A steady-state thermal model was used to predict the current-ratings for post-fault operation. Experimental tests were carried out for the purposes of verification.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Analysis of Dual Three-Phase Induction Machines under Post-Fault Operating Conditions


    Contributors:


    Publication date :

    2020-09-10


    Size :

    305459 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English