The proposed integrated power systems (IPS) of navy ships is based on an ungrounded system. However the natural capacitance of the cable and the EMI filters provide ground paths to the ship's hull. There is thus a "virtual ground" between the modules of the IPS. The fault current is very low for a single line to ground fault in this ungrounded system allowing continuous operation but also making fault detection difficult. In this paper a method of ground fault detection using wavelets is introduced. The ground fault conditions are simulated using PSPlCE and fault detection implemented with Daubechies wavelets. It is shown that ground faults can be detected by wavelet analysis of the line to line voltages.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    The application of wavelets to shipboard power system protection


    Contributors:
    Douglas, H. (author) / Pillay, P. (author) / Ortmeyer, T.H. (author)


    Publication date :

    2005-01-01


    Size :

    723730 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Integrated protection system design for shipboard power system

    Yanfeng Gong, / Yan Huang, / Schulz, N. | IEEE | 2005


    DC SHIPBOARD POWER SYSTEM

    European Patent Office | 2020

    Free access

    DC SHIPBOARD POWER SYSTEM

    KIM SEONG IL / DRAZEN DUJIC / KIM SOO NAM et al. | European Patent Office | 2020

    Free access

    An Adaptive Protection Scheme for Shipboard Power Systems

    Amoda, Oluwaseun. A. / Schulz, Noel . N. | IEEE | 2007


    Application of STATCOM for MVDC shipboard power system

    Babaei, Maziar / Jafari-Marandi, Ruholla / Abdelwahed, Sherif et al. | IEEE | 2017