Highly utilized permanent magnet synchronous machines (PMSMs) often show a significant inductance variation near and above the rated current values due to saturation. For precise modeling and control, the change in the parameters has to be considered by means of look-up tables. To parameterize these look-up tables, the inductances and the stator resistance have to be identified for various current set points. However, iron losses interfere with a precise identification if they are not considered. Therefore, an extended model is introduced to derive an identification method that considers and compensates for these effects. Measurement results prove the effectiveness of the proposed method.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Impact of iron losses on parameter identification of permanent magnet synchronous machines


    Contributors:


    Publication date :

    2011-09-01


    Size :

    1940855 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Efficient Method for Simulation of AC Losses in Permanent Magnet Synchronous Machines

    Silber, Siegfried / Klammer, Bianca / Kaspar, Kevin | IEEE | 2020



    AC Machines: Permanent Magnet Synchronous and Induction Machines

    Ranjbar, A. H. / Fahimi, Babak | Springer Verlag | 2021


    Scaling laws for synchronous permanent magnet machines

    Stipetic, Stjepan / Zarko, Damir / Popescu, Mircea | IEEE | 2015


    CONTROLLER ANTI-WINDUP FOR PERMANENT MAGNET SYNCHRONOUS MACHINES

    PRAMOD PRERIT / ZHANG ZHE | European Patent Office | 2019

    Free access