At present there is no standardized grounding method for medium voltage direct current (MVDC) shipboard power distribution systems. This paper introduces a method for selection of a maritime MVDC grounding scheme that considers technical acceptability, maintainability, reliability, safety, and feasibility. Several candidate grounding approaches and the results of the selection process are presented. In addition to the MVDC grounding method, a potentially suitable ground fault location approach based on noise pattern analysis is evaluated. The sensitivity of this fault location approach to source-ground capacitive coupling is analyzed using a notional two-zone MVDC ship distribution system model.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Grounding and fault location in power electronic based MVDC shipboard power and energy systems


    Contributors:


    Publication date :

    2017-08-01


    Size :

    825600 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English




    Primary and backup protection for fault current limited MVDC shipboard power systems

    Deng, Qiu / Liu, Xing / Soman, Ruturaj et al. | IEEE | 2015



    Application of STATCOM for MVDC shipboard power system

    Babaei, Maziar / Jafari-Marandi, Ruholla / Abdelwahed, Sherif et al. | IEEE | 2017


    Supercapacitor for High-Dynamic Load Management in MVDC Shipboard Power Systems

    Khan, Mohammed Masum Siraj / Smith, Brian Lehi / Parvania, Masood | IEEE | 2019