In a new formulation for digital phase-locked loops, loop-filter constants are determined from loop roots that can each be selectively placed in the s-plane on the basis of a new set of parameters, each with single and direct physical meaning in terms of loop noise band, width root-specific decay rate, or root-specific damping. Loops of first to fourth order are treated in the continuous-update approximation (B/sub L/T/spl rarr/0) and in a discrete-update formulation with arbitrary B/sub L/T. Deficiencies of the continuous-update approximation in large-B/sub L/T applications are avoided in the new discrete-update formulation. A new method for direct, transient-free acquisition with third- and fourth-order loops can improve the versatility and reliability of acquisition with such loops.<>


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Controlled-root formulation for digital phase-locked loops


    Contributors:


    Publication date :

    1995-01-01


    Size :

    9246712 byte




    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English



    Controlled-Root Formulation for Digital Phase-Locked Loops

    Stephens, S.A. | Online Contents | 1995



    Controlled-Root Approach To Digital Phase-Locked Loops

    Stephens, Scott A. / Thomas, J. Brooks | NTRS | 1995


    Parallel Digital Phase-Locked Loops

    Sadr, Ramin / Shah, Biren N. / Hinedi, Sami M. | NTRS | 1995