The mathematical analysis of a single-phase inductor alternator presented here asserts that rotor slot restrictions apply only for alternators with conventional double winding. Schemes using single winding for both dc excitation and single-phase output are developed and their designs are discussed. It is demonstrated that the proposed schemes are superior in performance to conventional schemes. Test results on a number of laboratory size machines fully support the theoretical findings.
Single-Winding Single-Phase Inductor Alternator
IEEE Transactions on Aerospace and Electronic Systems ; AES-12 , 6 ; 689-697
1976-11-01
2720878 byte
Article (Journal)
Electronic Resource
English
Inductor tied ultracapacitor module devoted to 12V battery starter alternator systems
Tema Archive | 2007
|