Advances in radiation therapy delivery systems have enabled motion compensated SBRT of the prostate. A remaining challenge is the integration of fast, non-ionizing volumetric imaging. Recently, robotic ultrasound has been proposed as an intra-fraction image modality. We study the impact of integrating a light-weight robotic arm carrying an ultrasound probe with the CyberKnife system. Particularly, we analyze the effect of different robot poses on the plan quality. Methods: A method to detect the collision of beams with the robot or the transducer was developed and integrated into our treatment planning system. A safety margin accounts for beam motion and uncertainties. Using strict dose bounds and the objective to maximize target coverage, we generated a total of 7650 treatment plans for five different prostate cases. For each case, ten different poses of the ultrasound robot and transducer were considered. The effect of different sets of beam source positions and different motion margins ranging from 5 to 50 mm was analyzed. Results: Compared to reference plans without the ultrasound robot, the coverage typically drops for all poses. Depending on the patient, the robot pose, and the motion margin, the reduction in coverage may be up to 50 % points. However, for all patient cases, there exist poses for which the loss in coverage was below 1 % point for motion margins of up to 20 mm. In general, there is a positive correlation between the number of treatment beams and the coverage. Conclusion: While the blocking of beam directions has a negative effect on the plan quality, the results indicate that a careful choice of the ultrasound robot’s pose and a large solid angle covered by beam starting positions can offset this effect. Identifying robot poses that yield acceptable plan quality and allow for intra-fraction ultrasound image guidance, therefore, appears feasible. ; Funded by Deutsche Forschungsgemeinschaft (Grants ER 817/1-1 and SCHL 1844/3-1).


    Access

    Download


    Export, share and cite



    Title :

    Robotic ultrasound-guided SBRT of the prostate: feasibility with respect to plan quality


    Contributors:

    Publication date :

    2016-07-12


    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English



    Classification :

    DDC:    629 / 610 / 600



    Impact of robotic ultrasound image guidance on plan quality in SBRT of the prostate

    Gerlach, Stefan / Kuhlemann, Ivo / Ernst, Floris et al. | BASE | 2017

    Free access

    Optimizing robot motion for robotic ultrasound-guided radiation therapy

    Schlueter, Matthias / Fuerweger, Christoph / Schlaefer, Alexander | BASE | 2019

    Free access

    Optimizing robot motion for robotic ultrasound-guided radiation therapy

    Schlüter, Matthias / Fürweger, Christoph / Schlaefer, Alexander | BASE | 2019

    Free access

    Remote Center of Motion for Redundant Robotic-Assisted Ultrasound Guided Regional Anesthesia

    Alkhatib, Mohammad / Novales, Cyril / Nouaille, Laurence et al. | TIBKAT | 2020