Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k-space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersampled reconstruction. Recently, joint motion correction and CS approaches have been proposed to partially correct for effects of motion. However, the main limitation of these approaches is that they can only correct for affine deformations. In this work, we propose a novel motion corrected CS framework for free-breathing dynamic cardiac MRI that incorporates a general motion correction formulation directly into the CS reconstruction. This framework can correct for arbitrary affine or nonrigid motion in the CS reconstructed cardiac images, while simultaneously benefiting from highly accelerated MR acquisition. The application of this approach is demonstrated both in simulations and in vivo data for 2D respiratory self-gated free-breathing cardiac CINE MRI, using a golden angle radial acquisition. Results show that this approach allows for the reconstruction of respiratory motion corrected cardiac CINE images with similar quality to breath-held acquisitions.


    Access

    Download


    Export, share and cite



    Title :

    Motion corrected compressed sensing for free-breathing dynamic cardiac MRI



    Publication date :

    2013-08-01


    Remarks:

    Usman , M , Atkinson , D , Odille , F , Kolbitsch , C , Vaillant , G , Schaeffter , T , Batchelor , P G & Prieto , C 2013 , ' Motion corrected compressed sensing for free-breathing dynamic cardiac MRI ' , Magnetic Resonance in Medicine , vol. 70 , no. 2 , pp. 504-516 . https://doi.org/10.1002/mrm.24463



    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English


    Classification :

    DDC:    531 / 629



    Joint cardiac and respiratory motion estimation for motion-corrected cardiac PET-MR

    Kolbitsch, Christoph / Neji, Radhouene / Fenchel, Matthias et al. | BASE | 2018

    Free access

    Compressed Air Breathing Apparatus for Helicopter Evacuation

    Gibbs, P.N.A. / Offshore Technology Conference | British Library Conference Proceedings | 2008


    Breathing sensing device

    PATRIKSSON OLA | European Patent Office | 2015

    Free access

    Underwater breathing and motion apparatus

    PAYRAVI ALIREZA | European Patent Office | 2022

    Free access

    UNDERWATER BREATHING AND MOTION APPARATUS

    PAYRAVI ALIREZA | European Patent Office | 2019

    Free access