PMSMs are widely used in applications on electric vehicles, robotics and mechatronic systems of industrial machinery. Thus it becomes increasingly interesting to prevent their fault or malfunctioning with Predictive Maintenance (PdM). However, reaching this outcome could be difficult, especially if the stationary condition is not achieved and without additional sensors. This paper examines the use of a load torque observer based on Extended Kalman Filter for the diagnosis of electric drives working under non-stationary conditions. The proposed Motor Torque Analysis (MTA) is compared with the Motor Current Signature Analysis by evaluating their diagnostic capabilities under the assumed conditions. Finally, the results of bearing failure detection under non-stationary conditions are presented, highlighting the superior diagnostic capabilities of the MTA under such conditions.


    Access

    Download


    Export, share and cite



    Title :

    Comparison of PMSMs Motor Current Signature Analysis and Motor Torque Analysis Under Transient Conditions



    Publication date :

    2021-01-01



    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Classification :

    DDC:    629



    Induction motor fault diagnosis : approach through current signature analysis

    Karmakar, Subrata / Chattopadhyay, Surajit / Mitra, Madhuchhanda et al. | TIBKAT | 2016



    Motor torque control method and device for engine transient working conditions

    ZHAO XIUMIN / GENG ZONGQI / ZUO LAN et al. | European Patent Office | 2020

    Free access


    Torque Ripple Reduction of PMSMs Using a Novel Angle-Based Repetitive Observer

    Tang M. / Formentini A. / Odhano S. A. et al. | BASE | 2020

    Free access