A 450 kW segmented arc heater facility is designed and its performance is analyzed using a computational code named ARCFLO4. The constrictor length is set to 46.2 cm, which allows a proper constrictor diameter and a nozzle throat diameter of 1.4 and 1.2 cm, respectively, considering the stability of arc discharge. It is shown that the calculated mass-averaged enthalpy values are within the range from 12.3 to . The ratio of the centerline enthalpy to the mass-averaged enthalpy in the nozzle throat region is about 1.22, which signifies a fairly uniform total enthalpy distribution. The wall heat fluxes are also calculated to provide the information needed for designing the cooling system.
Numerical Design and Performance Analysis of 450 kW Segmented Arc Heater
Journal of Thermophysics and Heat Transfer ; 28 , 2 ; 173-180