The paper deals with practical issues on adjusting and implementation of leaks diagnosis systems taking into account standards of the American Petroleum Industry. Considering a pilot pipeline developed specially for leak detection tests which is 132m long with 10.4 cm of diameter and it is instrumented with different kinds of flow and pressure sensors at the ends of the line, we share our experience about how to cope with practical aspects of the design and adjusting of multi-leaks decision systems including open issues. The study also shows the results of three detection methods tested with the same pipeline: a model-based observer, an identification approach and a data driven method.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Practical issues of leaks diagnosis in pipelines


    Beteiligte:
    Verde, C. (Autor:in)


    Erscheinungsdatum :

    2011


    Format / Umfang :

    6 Seiten, 9 Bilder, 17 Quellen




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Datenträger


    Sprache :

    Englisch




    Acoustic monitoring for detecting leaks in pipelines

    Rocha, S.M. / Haran, S. | Tema Archiv | 1991


    Gas Leaks through Corrosion Defects of Buried Gas Transmission Pipelines

    Eparu, Cristian / Albulescu, Mihai / Neacsu, Sorin et al. | Tema Archiv | 2014


    A neural model to detect and determine the magnitude of leaks in gas pipelines

    Barbosa Santos, Rejane / Orlandi de Sousa, Elisangela / Lucia da Cruz, Sandra et al. | Tema Archiv | 2011


    Features of the search for leaks in pipelines of heat networks using the acoustic-emission method

    Lapshin, B.M. / Ovchinnikov, A.L. / Chekalin, A.S. | Tema Archiv | 2011