High-strain linepipes provide excellent strain capacity to withstand axial compression and bending deformation. Assuming the outside diameter, the wall thickness and the design factor of the linepipe as 762 mm, 15.6 mm, and 0.4, respectively, critical compressive strain of the X80-grade linepipe can be estimated to be 2.0% which is approximately 1.5 times larger than that of a conventional X80-grade pipe. The excellent strain capacity enables us to reduce construction costs and ensure integrity of buried pipelines in seismic areas and cold regions.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Seismic integrity of high-strength pipelines


    Weitere Titelangaben:

    Erdbebensicherheit von hochfesten Pipelines
    Titel japanisch


    Beteiligte:
    Suzuki, Nobuhisa (Autor:in) / Igi, Satoshi (Autor:in) / Masamura, Katsumi (Autor:in)

    Erschienen in:

    JFE Giho ; 17 ; 14-19


    Erscheinungsdatum :

    2007


    Format / Umfang :

    6 Seiten, 6 Bilder, 8 Tabellen, 10 Quellen