Comparative data using airborne and settled methods of measuring particulate contamination have been obtained from various workstations associated with the manufacture and integration of ESA spacecraft. This data, the instrumentation and sampling techniques for measuring settled particulate contamination, and the need for basing a clean room standard on the values obtained from settled particulate contamination measurements are presented and discussed. (Stoehr)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Evaluation and comparison of airborne and settled particulate contamination for controlled environment workstations


    Weitere Titelangaben:

    Bewertung und Vergleich der Verunreinigung durch schwebende und niedergeschlagene Teilchen in der Reinraumtechnik


    Beteiligte:
    Davis, R.W. (Autor:in)


    Erscheinungsdatum :

    1979


    Format / Umfang :

    10 Seiten, 5 Bilder, 6 Tabellen, 3 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch