A seismic upgrading approach for super-large-span upper-deck concrete-filled steel tube arch bridges using the stayed buckle cables (SBCs, which are temporary facilities for construction of long-span arch bridges) was proposed. The arrangement of SBCs most beneficial to the seismic resistance of arch bridges was determined. The results show that the reasonable arrangement of SBCs can achieve significant seismic performance improvement, reduce the stress demand on the diagonal of the arch rib, and improve the capacity-demand ratios of the weak sections of the arch rib. In upgrading model, the max displacement response of the structure is decreased by 41.3%, the max tensile stress on the diagonal is decreased by 30.1%, the max compression stress demand on the diagonal decreased by 18.0%, the CDRs of sections of the arch ribs are greatly improved.
Stayed Buckle Cable Recycling for Seismic Upgrading of Super-long-span Concrete Filled Steel Tube Arch Bridges
KSCE J Civ Eng
KSCE Journal of Civil Engineering ; 28 , 2 ; 777-786
2024-02-01
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Instability issues in extremely long-span steel cable-stayed bridges
British Library Conference Proceedings | 1994
|Cost of Long Span Cable-Stayed Bridges with Application of High Strength Steel
British Library Conference Proceedings | 2009
|