This paper describes the design and qualification of this SCIAMACHY Radiant Cooler and focuses on the methods and results of the thermal balance and thermal verification test of the Radiator Reflector Unit flight model, performed late summer 1998.A new type of temperature control has been used that proved to increase speed, simplicity and accuracy of the test itself as well as the evaluation afterwards.The RRU TB/TV test was successful in gathering all significant thermal parameters.After refurbishment of the cooler door and a requalification test of its transient performance all cooler parameters are acceptable and its thermal performance is within specification.
Thermal Qualification of the Sciamachy Passive Cryogenic Cooler
Sae Technical Papers
International Conference On Environmental Systems ; 1999
1999-07-12
Aufsatz (Konferenz)
Englisch
The Design, Development and Qualification of the SCIAMACHY Radiant Cooler
British Library Conference Proceedings | 1997
|Design and qualification of methane-filled heat pipes for the SCIAMACHY radiant cooler
British Library Conference Proceedings | 1997
|Design and Qualification of Methane Filled Heat Pipes for the SCIAMACHY Radiant Cooler
SAE Technical Papers | 1997
|Design and qualification of methane-filled heat pipes for the SCIAMACHY radiant cooler
British Library Online Contents | 1997
|The development of the SCIAMACHY radiant cooler
British Library Conference Proceedings | 1997
|