This SAE Aerospace Recommended Practice (ARP) is intended to provide design and qualification requirements for self-displacing hydraulic accumulators. These requirements are intended be included in the Procurement Specification for the accumulator. Those requirements identified by the use of “shall” are considered to be essential requirements; those requirements identified by the use of “should” are considered to be optional requirements for inclusion in the Specification at the discretion of the Purchaser. In addition, test methods for production acceptance and qualification purposes are provided. The accumulator is intended for use in military aerospace hydraulic systems with rated pressures of up to 8000 psi (55 158 kPa) and of the following types as specified in AS5440: a Type I −65 to +160 °F (−54 to +71 °C) fluid temperature b Type II −65 to +275 °F (−54 to +135 °C) fluid temperature The accumulator is also intended for use in commercial aerospace and helicopter hydraulic systems. ARP4553 has been updated to Revision A for the following reasons: a New and revised technical and test requirements have been introduced b The references called up in the document have been updated c Editorial changes have been made to improve the readability of the document


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Aerospace - Accumulator, Hydraulic, Self-Displacing


    Erscheinungsdatum :

    19.12.2008



    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch