This SAE Aerospace Recommended Practice (ARP) is intended as a guide in defining the requirements for aerospace piston separated hydraulic accumulators, including details pertinent to the design, fabrication, and performance of the accumulator. This type of accumulator has a piston separator and contains both high-pressure gas and fluid. The accumulator is used in aerospace hydraulic systems of the following types as defined in AS5440 with design operating pressures of up to 8000 psi (55,160 kPa). Type I: -65 to +160 °F (-54 to +71 °C) fluid temperature Type II: -65 to +275 °F (-54 to +135 °C) fluid temperature For commercial aerospace or helicopter applications, the information and guidelines of ARP4752 or ARP4925 respectively, are considered. ARP4379 has been revised to issue A for the following reasons: Major editorial changes Document restructured and reformatted in its entirety to reflect latest industry practice and standards Vessel Proof and Burst factors changed for commercial to comply with new regulations Updated references New and revised technical and test requirements have been incorporated
Aerospace - Accumulator, Hydraulic, Cylindrical, Piston Separated
20.11.2007
Aufsatz (Konferenz)
Englisch
Aerospace - Accumulator, Hydraulic, Cylindrical, Piston Separated
SAE Technical Papers | 2016
Aerospace - Accumulator, Hydraulic, Self-Displacing
SAE Technical Papers | 2008
Accumulator, Hydraulic, Cylindrical Aircraft
SAE Technical Papers | 1991
Aerospace - Accumulator, Hydraulic, Welded Bellows, Factory Precharged
SAE Technical Papers | 2009
Aerospace - Accumulator, Hydraulic, Welded Bellows, Factory Precharged
SAE Technical Papers | 2009