This paper discusses the thermal modeling activities as a design and development tool for the Tracker Thermal Control System, the mechanically pumped, carbon dioxide thermal management system for the AMS-2 Silicon Tracker. Main modeling topics are: radiator sizing and condenser development, set-point control and pre-heating issues with respect to the spatial and temporal temperature gradient requirements of the Tracker.
Thermal Modeling Issues Concerning the Mechanically Pumped Two-Phase CO2 Cooling for the AMS-2 Tracker
Sae Technical Papers
International Conference On Environmental Systems ; 2002
2002-07-15
Aufsatz (Konferenz)
Englisch
Development of a Mechanically Pumped Two-Phase CO2 Cooling Loop for the AMS-2 Tracker Experiment
SAE Technical Papers | 2002
|Mars Pathfinder mechanically pumped cooling loop
NTRS | 2001
|Current Mechanically Pumped Two-Phase Thermal Control Loop Developments
SAE Technical Papers | 2004
|A Concept for a Miniature, Mechanically Pumped Two-Phase Cooling Loop
SAE Technical Papers | 2008
|