One of the key problems for active vibration control is to determine the position of actuators in the structure, which affects the efficiency and the cost of vibration active control system. In this paper, a new method is proposed to seek the optimal position of actuator in active vibration control. This paper use EER (Energy Efficiency Ratio) as the optimization rule under which GA (Genetic Algorithm) is used to seek the optimal position of actuator. The GARTEUR plane model is used as the research object for method validation. The new method is applied to seek the optimal position of actuator on the model which is used to control the simulated engine vibration problem. At last, an active vibration control experiment is conducted on the model to verify the applicability and effectiveness of this method. The result shows: The optimal position obtained by the new method can obviously improve the active vibration control effect on the model.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Optimal Placement of Actuators for Active Vibration Control Using EER and Genetic Algorithm


    Beteiligte:
    Chen, Jianding (Autor:in) / Jiang, Jinhui (Autor:in) / Wang, Ke (Autor:in) / Zhang, Fang (Autor:in)


    Erscheinungsdatum :

    01.07.2019


    Format / Umfang :

    301814 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch