In operation and testing of rocket engines using liquid propellents, it is desirable to continuously measure density of flowing liquid under transient conditions where changing temperature and pressure cause small density changes; to accomplish this, method was developed which comprises measuring electrical capacitance of calibrated concentric-cylinder capacitor inserted in rocket engine feed system; result indicates accuracy to plus or minus 1%.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Capacitance densitometer for determination of transient densities of cryogenic liquids


    Weitere Titelangaben:

    ARS J


    Beteiligte:

    Erschienen in:

    ARS Journal ; 31 , n 3


    Erscheinungsdatum :

    1961


    Format / Umfang :

    3 pages


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch


    Schlagwörter :


    Densitometer Patent