An advanced preprototype Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) has been developed to provide high quality water recovery from various types of wastewater on extended duration space flights. The subsystem has undergone extensive wastewater processing testing, in order to evaluate its potential as an essential part of the Space Station Water Reclamation System. A discussion of the operating performance of the TIMES is presented in this paper, with special attention given to the water quality attained for a number of simulated Space Station wastewater feedstocks.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Thermoelectric integrated membrane evaporation subsystem testing


    Additional title:

    Pruefung eines integrierten thermoelektrischen Verdunstungs-Subsystems mit Membran


    Contributors:
    Dehner, G.F. (author) / Price, D.F. (author)

    Published in:

    SAE-Papers ; Jul ; 1-5


    Publication date :

    1987


    Size :

    5 Seiten, 7 Bilder, 7 Quellen


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Thermoelectric Integrated Membrane Evaporation Subsystem Testing

    Price, Don F. / Dehner, Gerard F. | SAE Technical Papers | 1987


    Thermoelectric Integrated Membrane Evaporation Subsystem Operational Improvements

    Dehner, Gerard F. / Winkler, H. Eugene / Reysa, Richard P. | SAE Technical Papers | 1984



    A thermoelectric integrated membrane evaporation system

    Trusch, R.B. / Roebelen, G.J. | Tema Archive | 1978


    A New Membrane for the Thermoelectric Integrated Membrane Evaporative Subsystem (TIMES)

    Thibaud-Erkey, Catherine / Fort, James H. / Edeen, Marybeth A. | SAE Technical Papers | 2000