A physicomathematical model is proposed that connects the process of commutator clouding with the power released in the sliding contact. It is shown that commutator clouding arises when the melting point of copper is reached at contact points.
Analysis of the causes of commutator clouding in traction motors of electric locomotives
Analyse der Ursachen von Kommutatorstoerungen in den Fahrmotoren von Elektrolokomotiven
Soviet Electrical Engineering ; 57 , 4 ; 92-98
1986
7 Seiten, 2 Bilder, 1 Tabelle, 4 Quellen
Article (Journal)