In order to solve the problem of magnetization of bimetallic composite pipe, we establish a non-contact base pipe leakage detection model based on finite element simulation, determine the relationship between the magnetic field in the area where the tri-axis magnetic leakage sensor is located and the parameters of the magnetic excitation structure, quantitatively calculate the law of magnetization of the pipe wall under different excitation parameters, optimize the parameters of magnetic excitation structure, and obtain the range of excitation structure parameters required for the tri-axial magnetic leakage sensor to complete the non-contact base pipe detection. The magnetic excitation structure parameters required by the three-axis leakage sensor for non-contact base pipe detection can provide a basis for the design of the magnetic excitation device for bimetallic composite pipe detection.
Analysis and Research on Magnetic Leakage Simulation of Bimetallic Composite Pipe
Lect.Notes Mechanical Engineering
International conference on Advancement in Materials, Manufacturing, and Energy Engineering ; 2022 ; Xi'an, China September 23, 2022 - September 25, 2022
Recent Advances in Applied Mechanics and Mechanical Engineering ; Chapter : 23 ; 227-238
2023-08-09
12 pages
Article/Chapter (Book)
Electronic Resource
English
Engineering Index Backfile | 1903
|Tema Archive | 2006
|Hydraulic Analysis of Leakage from Submarine Pipe Network
Online Contents | 2015
|Brake pipe leakage and compressor capacity
Engineering Index Backfile | 1917
|