This paper introduces the working principle of a high-temperature high-speed wind tunnel and analyzes the necessity of coordinated control of fuel flow-rate for the fuel supply system. In order to achieve a coordinated control of fuel flow-rate, a proportional integral (PI) cross-coupled algorithm is designed. Because PI parameters in PI cross-coupled algorithm are invariant, a better control effect cannot be achieved when there are time-variant parameters in system, so a fuzzy PI adaptive cross-coupled algorithm with model reference is designed. The simulation and experimental results show that the fuzzy PI adaptive cross-coupled algorithm with model reference has better control quality compared with the PI cross-coupling control algorithm.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Coordinated control of fuel flow-rate for a high-temperature high-speed wind tunnel


    Contributors:
    Cai, Chaozhi (author) / Yang, Yumin (author) / Liu, Tao (author)


    Publication date :

    2016-11-01


    Size :

    11 pages




    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English