This SAE Aerospace Recommended Practice (ARP) establishes the minimum recommended Test Stand Setup and Procedures for inspecting and testing Aircraft Refuelers. The inspection and test procedure shall be used to evaluate the operation and performance of an Aircraft Refueler to assure that it meets the minimum refueling performance criteria and is fit for aircraft fueling and/or defueling operations. These procedures shall be used to test new Aircraft Refuelers and may be used to perform routine tests to confirm that the Aircraft Refuelers comply with the minimum performance criteria as specified herein. This document covers all types of Aircraft Refuelers, stationary (e.g., cabinet type units) or mobile (e.g., hydrant service vehicles, tankers, etc.). This SAE Aerospace Recommended Practice contains general criteria for the inspection and test procedure to be used to evaluate the operation and performance of an Aircraft Refueler. This revision ensures that all industry best practices and guidelines have been incorporated into the recommended practice to create synergy between the relevant global guidelines for the testing of flow performance of aircraft refuelers.