Abstract This paper presents a control method for a four-leg three-level flying capacitor converter (FCC) operating as a shunt active power filter (SAPF), based on model predictive control with finite number of control states (FS-MPC). Current control and capacitor voltage balancing are described. Influence of the mismatch of the inductive filter model parameters on the current control precision is analysed. Results are supported by the experimental waveforms obtained with a 10kVA set-up.
Model Predictive Control of Four-Leg Three-Level Flying Capacitor Converter: Influence of Model Parameter Mismatch
Power Electronics and Drives ; 3 , 1
2018
Article (Journal)
English
BKL: | 53.35 Stromrichter, Transformatoren / 53.33$jElektrische Maschinen und Antriebe / 53.33 Elektrische Maschinen und Antriebe / 53.35$jStromrichter$jTransformatoren |
Improved Model Predictive Control of Three-level Voltage Source Converter
Online Contents | 2014
|Analysis of Transients in a Three-Level DC–DC Flying Capacitor Converter. Time Domain Approach
Online Contents | 2019
|