A newly developed, 3-mm-diam, dual hot-wire aspirating probe was used to measure the time-resolved stagnation temperature and pressure in a transonic cryogenic wind tunnel. Measurements were taken in the freestream of the settling chamber and test section. Data were also obtained in the unsteady wake shed from an airfoil oscillating at 5 Hz. The investigation revealed the presence of large fluctuations in the settling chamber occuring at the blade passing frequency of the driving fan of the tunnel. These fluctuations decrease at the test section. The rms value of the fluctuating stagnation pressure decreased from 17.5 percent in the settling chamber to 3.7 percent in the test section. Fluctuating stagnation temperature decreased from 12.3 percent to 8.4 percent. Measurements in the wake of the oscillating airfoil showed a fluctuating stagnation temperature of as much as 42 K in rms value.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Cryogenic tunnel measurement of total temperature and pressure


    Contributors:
    Ng, W.-F. (author) / Rosson, J. C. (author)

    Published in:

    Publication date :

    1986-03-01



    Type of media :

    Miscellaneous


    Type of material :

    No indication


    Language :

    English







    Electronically Scanned Pressure Measurement Scanner for Cryogenic Wind Tunnel Applications

    Shams, Q. A. / Zuckerwar, A. J. / IEEE | British Library Conference Proceedings | 1999


    Surface Pressure Measurement in a Cryogenic Wind Tunnel by Luminescent Coating

    Asai, K. / Kanda, H. / Cunningham, C. T. et al. | British Library Conference Proceedings | 1997