In permanent magnet synchronous machines (PMSMs), the synchronous inductances have important influences on both steady state and dynamic performances, such as designing control strategies, predicting torque and flux-weakening capabilities. However, standard procedures for the inductance measurement have not been established yet. This paper presents a comprehensive analysis and comparative study of the various off-line methods that can be used to measure the inductances based on their accuracy, experimental setup and complexity. These approaches can be classified into three main categories: load test, DC standstill test and AC standstill test. Moreover, with the employment of finite element analysis (FEA), qualitative comparisons are done among these methods.