A Sagnac loop interferometer using polarization maintaining (PM) photonic crystal fiber was experimentally demonstrated and analyzed. Different filtering functions and reduced temperature dependence were observed. Experimental results agree well with simulations.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Sagnac loop interferometer using polarization maintaining photonic crystal fiber


    Contributors:
    Kim, D.-H. (author) / Kang, J.U. (author)


    Publication date :

    2005-01-01


    Size :

    939072 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Sagnac Loop Interferometer Using Polarization Maintaining Photonic Crystal Fiber

    Kim, D.-H. | British Library Conference Proceedings | 2005




    Temperature response of polarization-maintaining photonic crystal fiber based interferometer

    Jun Long Lim, / Hu, Dora Juan Juan / Shum, Perry Ping et al. | IEEE | 2011


    Mode-locked fiber laser using the Sagnac interferometer and nonlinear polarization rotation

    Ibarra-Escamilla, B. / Kuzin, E. A. / Haus, J. W. et al. | British Library Conference Proceedings | 2003