We demonstrate accurate ultrashort pulse autocorrelation measurements for coupled energy of 52 aJ per pulse using aperiodically poled lithium niobate waveguides. The corresponding sensitivity is 3.2/spl times/10/sup -7/ mW/sup 2/, about 500 times better than the previous record.