A model study of the fixed-cone valves for the New Melones Dam outlet works was conducted with the major emphasis on determining the differential pressures acting on the vanes of the valves. These pressures were measured along the vane, and the differential acting across the vane was used in a structural analysis by the Sacramento District. Flow entering the 66-in.-diam valves in the low-level outlet works was highly distorted by the combined bends located just upstream of the valves. The upstream bifurcations in the flood control and irrigation outlet system caused substantial fluctuation of flow entering the 78-in.-diam valves. The discharge characteristics of the valves showed that the eight-vaned valves (without the center connecting hub design) used in the New Melones Dam outlet works have discharge coefficients slightly higher than conventional four- and six-vaned valves with center connecting hub. Approach conduit pressures were measured at all potential low-pressure zones and no low pressures were measured. The original hood design was modified to reduce backsplash on the valves. In the low-level outlet works, the backsplash plate was moved downstream 4 ft from the original location and backsplash was substantially reduced. In the flood control and irrigation outlet system a divergent cone was used in lieu of the plate to reduce backsplash. Results of the study are considered valid for use in designing against fatigue failure of the vanes. Although frequency spectra developed from time-histories of pressure, strain, and dye injections determined that predominant frequencies were low, the possibility of a resonant failure cannot be ruled out. Therefore, prototype tests have been initiated to address this possibility and to provide model-prototype correlation.


    Access

    Download


    Export, share and cite



    Title :

    Fixed-Cone Valves, New Melones Dam, California: Hydraulic Model Investigation



    Published in:

    Publication date :

    1981


    Size :

    9232267


    Type of media :

    Report


    Type of material :

    Electronic Resource


    Language :

    English



    Classification :


    Fixed-Cone Valve Prototype Tests, New Melones Dam, California

    Fagerburg, Timothy L. | HENRY – Federal Waterways Engineering and Research Institute (BAW) | 1983

    Free access

    Flood Control and Irrigation Outlet Works and Tailrace Channel for New Melones Dam, Stanislaus River, California: Hydraulic Model Investigation

    Maynord, Stephen T. | HENRY – Federal Waterways Engineering and Research Institute (BAW) | 1981

    Free access

    Silent hydraulic valves

    Silva,G. | Automotive engineering | 1991


    Silent Hydraulic Valves

    Silva, Gabriel | SAE Technical Papers | 1991


    Fixed-Cone Valve Prototype Tests, Final Series, New Melones Dam, California

    Fagerburg, Timothy L. | HENRY – Federal Waterways Engineering and Research Institute (BAW) | 1984

    Free access