Abstract This paper investigates whether biased electrodes can improve the performance of a microwave-discharge water ion thruster, which has been proposed as a propulsion system for CubeSats. Previously, for several microwave ion sources, the beam currents have been increased by mounting a biased electrode in the discharge chamber. The effect of a biased electrode on a water ion thruster was unclear because its magnetic field profile and characteristic length compared with the microwave wavelength are different from those used in previous studies. To investigate the effect, a thruster was divided into three parts: magnets, a microwave antenna, and a discharge chamber, which is comprised of an electrically conductive sidewall and a screen grid. The parts were isolated electrically. Bias voltages from 44 to + 44V were applied to the microwave antenna or magnets by an additional power supply. These bias voltages were applied with respect to the screen grid and sidewall voltage. A maximum screen current of 12.7 mA was obtained for an antenna bias voltage of 38.2V. This is 2.3 times larger than the current without a bias voltage. This increase could be caused by a combination of an increase of plasma density and ion extraction efficiency. The plasma density could increase with the gain of the total absorbed power. The ion extraction efficiency could increase due to the change in the plasma potential distribution. Overall, the mass utilization efficiency of the water ion thruster increased from 3.3% to 7.9% and the discharge loss decreased from 280 to 150W/A at the antenna bias of 38V. The performance with water electron source was evaluated. The thrust force, specific impulse, thrust-to-power ratio, thrust efficiency were 190 μ N, 350s, 5.9 μ N/W, and 1.0%, respectively at the antenna bias of 25V.

    Highlights The performance of the water ion thruster with biased electrodes was evaluated. The electric potential of magnets or an antenna inside the thruster was changed actively. The screen current increased from 5.4 to 12.7 mA with positive potential on the antenna. An increase of the plasma density and the ion extraction efficiency caused the performance improvement. With antenna bias, the specific impulse was 350s, and thrust efficiency was 1%.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Improving the performance of a water ion thruster using biased electrodes


    Contributors:

    Published in:

    Acta Astronautica ; 187 ; 133-140


    Publication date :

    2021-06-13


    Size :

    8 pages




    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English




    Hall thruster with absorbing electrodes

    Fruchtman, A. / Fisch, N. / Raitses, Y. | AIAA | 2000


    Pulsed Plasma Thruster Using Water, Part II: Thruster Operation and Performance Evaluation

    Scharlemann, Carsten / York, Thomas / Kamhawi, Hani | AIAA | 2003


    Thermal phenomena of MPD thruster electrodes

    KUWAHARA, K. / UEMATSU, K. / SUZUKI, H. et al. | AIAA | 1985



    PIC-DEM MODELING OF VACUUM ARC THRUSTER ELECTRODES

    Brieda, Lubos / Zolotukhin, Denis B. / Keidar, Michael | TIBKAT | 2021