Findings are summarized from an internal research study to determine applications and limitations of the impact echo scanning (IES) system for void detection in posttensioned bridge ducts. The nominal thickness of the test panels ranged from 0.2 to 0.7 m with plastic and steel ducts inside. The diameter of the ducts ranged from 50 to 120 mm. One tapered section (with wall thicknesses between 0.2 to 0.7 m) had draped ducts, with the rest being straight ducts. Impact echo (IE) testing was performed using the IE scanner system. This system, as rolled, automatically performs an IE test at 25-mm (1-in.) intervals. All IE scans in this investigation were performed on lines perpendicular to the general posttensioned duct direction. The maximum frequency of excitation of the impactor in the scanner used in research is 25 kHz. This internal research is an expanded study from a previous research project funded by the NCHRP-IDEA program titled Nondestructive Evaluation Method for Determination of Internal Grout Conditions Inside Bridge Posttensioning Ducts Using Rolling Stress Waves for Continuous Scanning. The purpose of the study was to better understand the nominal thickness limitation of the structures for IE tests, using a scanner with a maximum excitation of 25 kHz to correctly identified voids in posttensioned bridge ducts.


    Zugriff

    Download

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Applications and Limitations of Impact Echo Scanning for Void Detection in Posttensioned Bridge Ducts


    Weitere Titelangaben:

    Transportation Research Record: Journal of the Transportation Research Board


    Beteiligte:
    Tinkey, Yajai (Autor:in) / Olson, Larry D. (Autor:in)


    Erscheinungsdatum :

    01.01.2008




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch





    Sensitivity Studies of Grout Defects in Posttensioned Bridge Ducts Using Impact Echo Scanning Method

    Tinkey, Yajai / Olson, Larry D. | Transportation Research Record | 2007


    Time Domain Reflectometry for Void Detection in Grouted Posttensioned Bridges

    Chajes, Michael / Hunsperger, Robert / Liu, Wei et al. | Transportation Research Record | 2003


    Ultrasonic C-Scan Imaging: Preliminary Evaluation for Corrosion and Void Detection in Posttensioned Tendons

    Iyer, Shivprakash / Schokker, Andrea J. / Sinha, Sunil K. | Transportation Research Record | 2003