The basic faults detection logic of fuel flow metering valve can not detect all the faults. It may cause un-commanded in-flight shut-down (IFSD) on the aero-engine and threat the flight safety. The operation principle of fuel flow metering valve is introduced in this paper. The basic faults detection logic is given. Two IFSD examples are presented. To reduce the un-commanded IFSD, faults detection logic updating is discussed. It can be used to design the new control software of the aero-engine and improve the aero-engine’s reliability.
Faults Detection Logic Updating of Fuel Metering Valve on Aero-Engine
Advanced Materials Research ; 503-504 ; 1660-1663
12.04.2012
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Fault diagnosis method for clamping stagnation of fuel metering valve of aero-engine
Europäisches Patentamt | 2023
|GAS FUEL METERING - Gas Fuel Metering Valve Announced
Online Contents | 1998
Valve Wizard reduces aero-engine valve maintenance time
Emerald Group Publishing | 2008
Aero-engine fuel regulator detection circuit and detection method
Europäisches Patentamt | 2023
|Bristol-perseus XII sleeve-valve aero engine
Engineering Index Backfile | 1938