A connector subassembly for an automotive High Intensity Discharge (HID) lamp failed at 672 hour salt fog test. The connector backshell, made from either nickel plated or anodized A413.0 aluminum alloy, corroded heavily where a braided electromagnetic interference (EMI) shield was attached. Pitting corrosion enhanced by the presence of chloride ions and a galvanic cell is the cause. Five design concepts are evaluated and then ranked based on cost, assembly easy, schedule impact, and aesthetics. For the leading design, the nickel plated backshell remained, but a nickel plated braid and polymer clamp replaced the existing shield and clamp.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Corrosion of a high intensity discharge lamp


    Weitere Titelangaben:

    Die Korrosion an einer Hochintensitäts-Entladungslampe


    Beteiligte:
    Smith, M.L. (Autor:in) / Sakaguchi, K. (Autor:in) / Carroll, C. (Autor:in) / Gabriel, T. (Autor:in) / Es-Said, O.S. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1995


    Format / Umfang :

    17 Seiten, 14 Bilder, 10 Tabellen



    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Corrosion of a High Intensity Discharge Lamp

    Carroll, Cliff / Sakaguchi, Kenneth / Smith, Martin L. et al. | SAE Technical Papers | 1995


    Litronic, a headlamp with high intensity gas discharge lamp (HID)

    Bertling,J. / Robert Bosch,Stuttgart,DE | Kraftfahrwesen | 1993


    Development and Evaluation of an Advanced Water-Jacketed High Intensity Discharge Lamp

    Barta, Daniel J. / Giacomelli, Gene A. / Sadler, Phil et al. | SAE Technical Papers | 2003



    Design Strategy for Free-Form Reflector Head Lamp Using High Intensity Discharge Light Source

    Wang, B. / Kreysar, D. / Jiao, J. et al. | British Library Conference Proceedings | 1997