The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses and two traditional masonry Chinese shophouses to examine their indoor thermal environments. The results of the former showed that the indoor air temperatures were higher than the outdoor air temperatures by 1 °C during daytime under open window conditions and 2 °C at night under closed window conditions on average. The emphasis was on reducing the temperature of the outdoor air before entering the lightweight house for bodily cooling by cross ventilation. The outdoor air temperature at the Malay house sites was lower than that of the terraced house site by 1.7 °C on average. The results of the latter revealed that indoor air temperatures in rooms that were adjacent to small internal courtyards were lower than the immediate outdoors by about 5 °C on average at the peak period. At night, the indoor air temperatures maintained values that were similar to the outdoors. The small courtyards were effective to cool the high thermal mass structures through nocturnal ventilative and radiative cooling. When assessed using an adaptive thermal comfort equation for hot–humid climates, the periods of indoor operative temperatures exceeding the 80% comfortable upper limit in the Malay houses, Chinese shophouses, daytime ventilated and night ventilated terraced houses were 47%, 7–8%, 91% and 42%, respectively, on fair weather days. Potential passive cooling techniques for the existing terraced houses including night ventilation, roof or ceiling insulation, window and wall shading, small courtyard concept, and microclimate modification and/or urban heat island mitigation were discussed.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot–humid climate of Malaysia


    Beteiligte:

    Erschienen in:

    Solar Energy ; 114 ; 229-258


    Erscheinungsdatum :

    2015


    Format / Umfang :

    30 Seiten, 39 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch





    Comparative Assessment of Air Distribution Systems : Improving Indoor Thermal Comfort in Office Spaces (AIAA 2016-1364)

    Khalil, Essam E. / Zeid, Ahmed Abou | British Library Conference Proceedings | 2016


    Influence of Urban Microclimate on Air-Conditioning Energy Needs and Indoor Thermal Comfort in Houses

    Liao, Feng-Chi / Cheng, Ming-Jen / Hwang, Ruey-Lung et al. | Tema Archiv | 2015


    Improving thermal seat comfort

    Hyundai Motor,KR / Gentherm,US / ThermoAnalysis,US et al. | Kraftfahrwesen | 2015


    Method and device for improving indoor comfort of excavator

    FU XINWEI / CHEN WEIXIONG / CHEN HUIJUN et al. | Europäisches Patentamt | 2020

    Freier Zugriff