Because of the configuration of the single-phase PWM converter in the traction system of EMU, there exists a voltage ripple in the DC-link, which is twice the frequency of the grid. The DC ripple voltage will impact the characteristic of the motor and cause torque and current pulsation, which is called beat phenomenon. In this paper, the origin of the fluctuating DC voltage is analyzed first, and the relations among the torque ripple, the current ripple, and the DC voltage ripple are derived from the analytical model of the traction system. A beat-less control scheme based on the frequency-domain analysis is proposed, and a compensation loop is applied to modify the slip frequency of the motor, thus minimizing the torque and current ripple. The algorithm is verified by simulation.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Research on Beat-Less Control Strategy Based on Frequency-Domain Analysis


    Beteiligte:
    Dong, Kan (Autor:in) / Diao, Lijun (Autor:in) / Zhao, Leiting (Autor:in) / Chen, Yizhou (Autor:in) / Liu, Zhigang (Autor:in)


    Erscheinungsdatum :

    2014


    Format / Umfang :

    13 Seiten





    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Beat-less control of electrolytic capacitor-less air conditioning motor drive system

    Wang, Gaolin / Yu, Chaohui / Zhao, Nannan et al. | IEEE | 2017


    Altimeter uses constant beat frequency

    Klass, P.J. | Tema Archiv | 1969


    JR Central adopts strategy to beat airline

    Knutton, Mike | IuD Bahn | 2001


    Beat-Frequency/Microsphere Medical Ultrasonic Imaging

    Yost, William T. / Cantrell, John H. / Pretlow, Robert A., III | NTRS | 1995