In this paper, a time domain reflectometry-based system for locating leaks in underground pipes (made of any material) is presented. The proposed system simply requires that a biwire should be attached to the pipe (all along its length), at the time of installation. Basically, the biwire acts as a permanent sensing element that can be connected to the measurement instrument whenever it is necessary to check for the presence of leaks. It is worth emphasizing that such a simple and low-cost system could tremendously facilitate leak detection not only in water distribution systems but also in wastewater/sewer pipelines. The proposed system was validated through measurements on a newly installed pilot plant, in which a leak was intentionally provoked.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    A TDR-based system for the localization of leaks in newly installed, underground pipes made of any material


    Beteiligte:
    Cataldo, A. (Autor:in) / Cannazza, G. (Autor:in) / De Benedetto, E. (Autor:in) / Giaquinto, N. (Autor:in)

    Erschienen in:

    Measurement Science and Technology ; 23 , 10 ; 105010/1-105010/9


    Erscheinungsdatum :

    2012


    Format / Umfang :

    9 Seiten, 35 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch





    Continuous underground monitoring of gas leaks

    Khalil, G.E. / Kimura, F. / Chin, A. et al. | Tema Archiv | 2005


    Rehabilitating underground pipes

    Sorrell, P. | Tema Archiv | 1995



    Angle-adjustable intelligent signal lamp installed underground

    CHENG TAIJUN | Europäisches Patentamt | 2020