This study was undertaken to investigate and understand the complete post-wrinkling behavior and failure modes of pressured X52-grade wrinkled buried energy pipeline when subjected to monotonically increasing bending deformation. This study involved both experimental and numerical investigations. Detailed parametric study was undertaken using a numerical approach, and it was found that the X52-grade steel linepipe generally exhibits a ductile behavior. The parametric study shows that X52 linepipe with a diameter-to-thickness ratio of 35 or higher does not fail in rupture. However, these linepipes eventually fail in a deformation mode due to excessive cross-sectional deformation. It was also found that the rupture failure occurs only at the wrinkle face of the bent linepipe.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Failure of X52 wrinkled pipeline subjected to monotonic bending deformation and internal pressure


    Weitere Titelangaben:

    Bruch einer mit Falten behafteten Rohrleitung aus Stahl der Güte X52, die einer ständigen gleichförmigen Biegeverformung und einem Innendruck ausgesetzt ist


    Beteiligte:
    Zhang, Yonghong (Autor:in) / Das, Sreekanta (Autor:in)


    Erscheinungsdatum :

    2008


    Format / Umfang :

    6 Seiten, 13 Quellen



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch




    Fracture of wrinkled pipes subjected to monotonic deformation: An experimental investigation

    Ahmed, Arman U. / Aydin, Mehmet / Cheng, J.J. Roger et al. | Tema Archiv | 2011



    Behaviour of wrinkled linepipe subjected to internal pressure and eccentric axial compression load

    Nazemi, N. / Kenno, S. / Das, S. | British Library Online Contents | 2009



    Burst Pressure Predictions of Composite Cylindrical Vessels with Wrinkled Plies

    Goyal, Vinay / Rome, Jacob / Klug, John | AIAA | 2005