A numerical procedure for the rapid prediction of the compression wave generated by a high-speed train entering a tunnel was presented and validated by Howe et al. . The method was devised to deal principally with compression wave generation in long hoods typically of length ~10 times the tunnel height and 'vented' by means of a series of windows distributed along the hood walls. Hoods of this kind will be needed to control wave generation by newer trains operating at speeds U exceeding about 350 km/h. In this paper experimental results are presented and compared with predictions in order to extend the range of applicability of the numerical method of Howe et al. (2006) to include short hoods with lengths as small as just twice the tunnel height (the situation for most hoods currently deployed on the Japanese Shinkansen) and for U as large as 400 km/h.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Rapid calculation of the compression wave generated by a train entering a tunnel with a vented hood: Short hoods


    Weitere Titelangaben:

    Schnelle Berechnung der Kompressionswelle eines Zuges bei Einfahrt in einen Tunnel mit belüftetem Rinlaßbereich: Kurzer Einlaß


    Beteiligte:
    Howe, M.S. (Autor:in) / Winslow, A. (Autor:in) / Iida, M. (Autor:in) / Fukuda, T. (Autor:in)

    Erschienen in:

    Journal of Sound and Vibration ; 311 , 1/2 ; 254-296


    Erscheinungsdatum :

    2008


    Format / Umfang :

    43 Seiten, 14 Bilder, 3 Tabellen, 17 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch