A previously developed first-principles-based equation for potential attenuation along marine pipelines and risers with multiple, equally spaced, identical galvanic anodes was modified to accommodate an error in its derivation. Both the original and modified equations account for the electrolyte (anode), coating, polarization, and metallic path resistances and, as such, represent improvements over previously available representations. Coordinate mapping-based finite difference method (CoMB-FDM) solutions are presented; and to the extent possible, accuracy of the proposed modified equation is verified.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    A modified potential attenuation equation for cathodically polarized marine pipelines and risers


    Weitere Titelangaben:

    Eine modifizierte Potentialdämpfungs-Gleichung für den kathodischen Korrosionsschutz von Meerespipelines und -steigleitungen


    Beteiligte:
    Lysogorski, D. (Autor:in) / Hartt, W. (Autor:in) / Ananthakrishnan, P. (Autor:in)

    Erschienen in:

    Corrosion, Houston ; 59 , 8 ; 684-687


    Erscheinungsdatum :

    2003


    Format / Umfang :

    4 Seiten, 3 Bilder, 2 Tabellen, 3 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :