For the past several years, manufacturers have been developing emission measurement systems for Super Ultra Low Emission (SULEV) measurements. The Bag Mini-Diluter (BMD) with an advanced exhaust flow measurement device is designed as an alternative to the traditional method for sampling vehicle exhaust, the Constant Volume Sampler (CVS). Exhaust sampling instruments require system verification tests. The system verification test described and mandated for the CVS in the Code of Federal Regulations (CFR) § 86.119-90(c) is a simulated test with propane. The very low concentration measurements required for SULEV regulations demand a more enhanced and accurate verification technique and procedure than the method described in the CFR. This investigation focuses on the technique and necessary equipment for verifying system integrity of the entire emission sampling system, including the Bag Mini-Diluter and the exhaust flow measurement device in the test cell. The technique involves the precisely controlled injection of an inert check gas SF6 (sulfur hexafluoride) into the exhaust gas stream. This technique has significant advantages over the propane injection for the CVS check since the check gas (SF6) is absent from the background measurement providing more accurate detection. Additionally, the check test is also run in situ. This test is a real verification of system integrity performed during an automotive test cycle, not just a simulation like the propane injection. Measurement of this test gas (SF6) relies on a sensitive NDIR (NonDispersive InfraRed) analyzer. In this investigation, practical operational suggestions are presented along with data to show the efficacy of the verification system.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    An investigation of SF6 gas for testing instrumental integrity of the emerging SULEV/PZEV measurement technology


    Weitere Titelangaben:

    Untersuchung von Schwefelhexafluoridgas für die Prüfung der gerätetechnischen Integrität der sich entwickelnden SULEV/PZEV-Meßtechnik


    Beteiligte:
    Porter, S. (Autor:in) / Rooney, R.T. (Autor:in) / Oestergaard, K. (Autor:in) / Rauker, Z. (Autor:in) / Ohtsuki, S. (Autor:in)


    Erscheinungsdatum :

    2002


    Format / Umfang :

    9 Seiten, 8 Bilder, 4 Tabellen, 3 Quellen




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    An Investigation of SF6 Gas for Testing Instrumental Integrity of the Emerging SULEV/PZEV Measurement Technology

    Oestergaard, Karl / Rooney, Richard T. / Ohtsuki, Satoshi et al. | SAE Technical Papers | 2002


    An Investigation of SF6 Gas for Testing Instrumental Integrity of the Emerging SULEV/PZEV Measurement Technology

    Porter, S. / Rooney, R. T. / Oestergaard, K. et al. | British Library Conference Proceedings | 2002



    Das BMW SULEV (PZEV) Konzept - Emissionsreduzierung ohne Kompromisse

    Liebl, J. / Hofmann, R. / Melcher, T. | Tema Archiv | 2003


    The BMW SULEV (PZEV) Concept - Emissions Reduction without Compromises

    Liebl, J. / Hofmann, R. / Melcher, T. et al. | British Library Conference Proceedings | 2002